  Email: boe@boeep.com
Solutions for Mechanical Screen Faults
You are here: Home » News » industry information » Solutions for Mechanical Screen Faults

Solutions for Mechanical Screen Faults

Views:20     Author:Site Editor     Publish Time: 2018-12-19      Origin:Site

Solutions for Mechanical Screen Faults

Winter has arrived at the Northern Hemisphere. Some problems of the wastewater screening machines are exposed gradually.

In this topic, BOEEP will instruct you the solutions for mechanical screen faults.


Problem-1: The effect of slag removal is not satisfying

Main CauseSolution
Tooth rake is not in placeAdjust position
Excessive horizontal error for tooth rakeReadjust
Worn tooth rakeRepair or replace
Installation angle is too largeReadjust
Damage of grille barsRepair or replace
Debris on the trackClear away
Friction or collision between traveling wheel and trach due to large installation errorAdjust, repair or replace
Damage of traveling wheelReplace

solutions for fine bar screen


Problems-2: Abnormal noise

Main CauseSolution
Obstruction when the rake movesAdjust or repair
Bearing damageReplace
Too much sediment at the bottom of the rotary drum screenClear away
Friction or collision between traveling wheel and trach due to large installation errorAdjust, repair or replace
Excessive or uneven gap of couplingReadjust
There are debris on the trackClear away

solutions for rotary drum screen


Problems-3: Damage to wire rope or chain

Main CauseSolution
Lack of maintenanceGrease or replace
Long-term wear or tearRepair or replace
Chain drops outReplace
Unilateral ware due to uneven force on both sidesAdjust, repair or replace


Problems-4: Great vibration of mechanical screen

Main CauseSolution
Excessive or uneven gap of couplingReadjust
The horizontal error of drum screen is too largeReadjust
There are debris on the trackClear away
Friction or collision between traveling wheel and trach due to large installation errorAdjust, repair or replace

solutions for drum screen filter

Problems-5: Irregular working of Reducer

Ref: Faults and solutions for reducer


Problems-6: Irregular working of Motor

Ref: Faults and solutions for motor


BOEEP has over 20 years’ professional experience as a waste water treatment equipment manufacturer and engineering service enterprise.

PRODUCTS

QUICK LINK

CONTACT US

Add:NO.88 Zhaozhuang Road, Yangmiao, Hanjiang, Yangzhou, Jiangsu, China
Tel:+86-514-87848766
Fax:+86-514-87894600
E-mail :boe@boeep.com
Hand phone: +86-15805271086
QQ: 2889871506
Skype/Wechat/Whatsapp:+86-15805271086
Copyright ©️ 2018 Jiangsu BOE Environmental Protection Technology CO., Ltd.  Designed by Leadong  / Site Map